Supernode 2

Edit on GitHub

Last updated April 8, 2019 by Brian

⚠️ Supernode 2 is no longer active. The sector antennas were moved to Soft Surplus ⚠️

Supernode 2 (node 570) was located at 1196 Metropolitan Avenue in Brooklyn New York. On October 7th, 2018 it was taken down due to roof repair.

The information below is a point of reference for how supernode 2 was configured.

Supernode 2 radios

Status

https://stats.570.nycmesh.net

Coverage

Supernode 2 coverage

Photos

Point-to-point link to node 227 The router Battery backup

Hardware

DescriptionModelManufacturerQuantity
RouterHex PoEMikrotik1
Point-to-point radioAirFiber 24UBNT1
Point-to-point radioNanobeam ACUBNT1
Wide area APLiteAP 120UBNT2
Indoor APUniFi APUBNT1
Application serverRaspberry PiRPi Foundation1
Inverter/Charger/ATSAPS700HFTripp Lite2
BatteryEXP12180ExpertPower1

Schematic

Backhaul

A pair of AirFiber 24s was donated to NYC Mesh and was deployed between 227 and 570 to provide Brooklyn with a near 1Gbps backhaul link to Supernode 1, the Manhattan area of the mesh and the internet.

Battery backup

Shortly after initial installation we noticed the node would go down on a somewhat regular basis. After some investigation and discussion with building residents, the culprit was revealed to be a circuit breaker being tripped by power hungry air conditioners. To insulate the node against short power outages like this we built a simple backup power system out of a 12 volt battery and integrated inverter / charger / automatic transfer switch.

Routing

570 currently uses BGP to exchange routes with its mesh peers. We hope to upgrade this node to support more dynamic routing protocols soon.